Thermal Compact Hood – Test Enclosure
TA-5000 ThermalAir Accessory
ThermalAir Compact Hood/Test Enclosure is for temperature testing semiconductor devices, automotive sensors, fiber optic components, microwave hybrids, MCM, PCB or any type of electronic / non-electronic parts. ThermalAir Compact Hood can integrate to your test setup.
The ThermalAir TA-5000 can bring precise thermal capabilities directly to your test application localizing the test where it’s required.
Our new thermal test technology gives the end user the ability to easily test while controlling the ramp rate speed with one touch temperature set point functions.
An Evolution in Localized Environmental Testing Equipment

-60°C to +200°C
Thermal Test Enclosure – Small Test Chamber – Environmental Testing Enclosure – Environmental Test Enclosure – Benchtop Environmental Test Chambers
Thermal Test Enclosure
TA-5000A with Hood

     -80°C to +225°C
ThermalAir TA-5000A Compact Hood Style Chamber is for temperature testing all types of components such as Automotive Parts, Sensors, Fiber Optic Transceivers, Microwave Devices, MCM, PCB, and all type of Electronic / Non-Electronic parts and other test articles.
The ThermalAir TA-5000A delivers a precise thermal stream of hot or cold dry air -80°C to +225°C capabilities directly to your test application, exactly localizing to where thermal conditioning and temperature cycle test Hot & Cold is required.
ThermalAir TA-5000A Compact Hood Style Chamber is a thermal test enclosure that can be raised and lowered down over unit under test for quick and easy loading / unloading parts right on your test station bench test fixture that need temperature thermal conditioning. Temperature test and cycle your electronic / non-electronic parts and other test articles and devices at temperatures from -60° to +200°C with Hood Style Chamber at temperature accuracy and uniformity, unmatched by standard environmental temperature test chambers.
  Download the Datasheets
Thermal Test Chamber – Benchtop Environmental Test Enclosure – Thermal Test Chamber – Benchtop Test Chambers – Small Thermal Test Chamber
Electronics and Electromechanical components continue to infiltrate all aspects of commercial and industrial use. Temperature test of these devices, components and parts in manufacturing for consumer or industrial markets are required to assure quality and reliability.
Military Defense to Consumer Electronics to Transportation to Cloud Computing Data Centers demand safety, performance, and reliability continues to grow. These components require temperature conditioning and fast temperature cycling at ranges from as cold as -100C to +300C and beyond.
- No LN2 or CO2 Required
- Interchangeable Compact Chamber Sizes
- Feed-Thru for Connecting Test Cables, Plugs, Â and Connectors to Device Under Test
- Fast Ramp Rates &Â Temperature Transition Times (User Controlled)
- Additional Internal Temperature Probe (Location Defined by User Placement)
Download the Datasheets

Thermal Test Enclosure – Test Chamber – Environmental Testing Enclosure – Thermal Test Chamber – Benchtop Temperature Test Enclosure

-80°C to +225°C
MPI Thermal localized temperature inducing test equipment brings temperature to your test. MPI thermal systems are portable and can easily be moved from one test station to another. Temperature cycling, thermal profiling and other environmental temperature conditioning is why MPI Thermal systems are part of the manufacturing temperature test processes.
The ThermalAir TA-5000A systems with the Hood Style temperature test enclosure provides heating and cooling for all types of materials. MPI’s thermal test enclosures & chambers are ideal for thermal testing and cycling various temperature ranges on parts and electronic components.
ThermalAir TA-5000A small temperature test enclosure meets the mil-spec temperature range of -55°C to +125°C (actual test range -80°C to +225°C). Fast temperature ramp rates for thermal cycling test in just seconds.
Download the Datasheets
Benchtop Environmental Chamber Chamber – Thermal Test Chamber – Temperature Testing Chamber – Temperature Cycling Test – Temperature Testing Chamber
Control the Ramp Rate Transition Times
ThermalAir temperature cycling test enclosure easily exceeds the mil-spec temperature range of -55°C to +125°C (actual test range -80°C to +225°C). Fast temperature cycling test in just seconds.
The DC chiller and DC Heater patented technology runs at full temperature performance at any power frequency, 200VAC to 250VAC users facility with 50% greater energy efficiency.
Thermal Shock Chamber – Small Temperature Chamber – Thermal Test Chamber – Environmental Test Enclosure – Small Test Chamber
Environmental Testing Solutions
The ThermalAir TA-5000 can bring precise thermal capabilities directly to your test application localizing the test where it’s required. ThermalAir TA-5000 Compact Chamber Hood can be raised up and lowered down over your components under test. Temperature test and cycle your electronic and non-electronic parts and other devices at temperatures from -60°C to +200°C with a temperature accuracy and uniformity unmatched by large environmental chambers.
Download the Datasheets
Thermal Hood – Temperture Test Enclosure

-60°C to +200°C

Download the Datasheets
Performance
Temperature Change Rate (in seconds)
Ambient to +125°C                      < 3 minutes
+125°C to Ambient                     < 2 minutes
Ambient to -40°C                       < 3 minutes
-40°C to Ambient                      < 1 minute
Uniformity                        2.0°C range from setpoint
1) For Optimal performance, use Compact Chamber closests in size to the UUT.
2) Performance is is measured on Compact Chamber using TA-5000A at 18cfm air flow rate.
ThermalAir Test Chambers & Accessories
The ThermalAir series of temperature testing and thermal cycling test systems have a wide range of accessories that are attached to the ThermalAir Stream Arm and Flex Hose located at the end of Thermal Head output gas nozzles.
They incorporate an intuitive full funtion for the ThermalAir users with the flexibility to accurately test in a variety of ways at the thermal test workstation.
The TA-5000A and TA-3000A series can also be used with an Thermal End Effector adaptors interfaced to the end of Thermal Head Arm and Stand, designed to adapt to the end users device under test. The exact use of this device depends on the users thermal test application.
Customize Your Temperature Testing Application