TA-5000A with Glass Cap
Flexible Temperature Simulation Test system
The ThermalAir TA-5000A brings precise thermal testing capabilities directly to your test application. Bring temperature to the test site where thermal conditioning is required. In the engineering test laboratory or on the manufacturing production test floor, the ThermalAir TA-5000 temperature test systems provide flexible test solutions for an array test applications and technologies.
An Evolution in Localized Temperature Cycle Test Equipment
Thermal Conditioning | Temperature Conditioning System | Thermal Characterization | Temperature Characterization | Thermal Characterization System | Temperature Characterization System
TA-5000A with Glass Cap
OUTPUT TEMPERATURE CONTROL
ThermalAir TA-5000A can control by user setting, the ramp rate, temperature transition time as fast as -55°C to +125°C in less than 10 seconds.
HOW DOES IT WORK
The TA-5000’s built-in air dryer and filtering system sends clean dry air (CDA) through its powerful internal chiller / heat exchanger to delivers hot & cold temperatures from -80°C up to +225°C.
User can control flow rate from 4 to 25 SCFM. The ThermalAir temperature systems are all self-contained. You just plug it in and it’s ready to start thermal testing your parts. [No configuration required]
Download the Datasheets
Thermal Conditioning | Temperature Conditioning System | Thermal Characterization | Temperature Characterization | Thermal Characterization System | Temperature Characterization System
Remote interface ports: IEEE-488, RS232C, SOT/EOT/SFF, And Ethernet, 4 USB-Type A, 1 USB-Type B, VGA, LAN, PLUS Auto Start Test & End of Test for automatic temperature cycling Hot-Cold-Amb. All this makes for simple control and service ability.
Download the Datasheets
Outputs a controlled clean dry thermal air stream directly on your test part
System Performance
Airflow: High capacity 10 l/s (20 scfm) continuous airflow optimizes temperature transition rate and throughput.
Typical Temperature transition rate:-55° to +125°C: approximately 10 seconds+125° to -55°C: approximately 10 seconds
Temperature Control: Environment Air or External DUT sensing directly at the DUT case to ±1.0°C
Temperature control Sensor Ports: Type T or Type K thermocouple, and 100 ohm RTD
Temperature set, display and resolution: ±0.1°C
Temperature Accuracy: 1.0°C ( calibrated to NIST standard)
Download the Datasheets
Thermal Air Forcing System
MPI ThermalAir temperature forcing systems provide a direct thermal stream of clean dry hot and cold air directly to the part that needs to be thermal tested. In the lab or on the production floor, ThermalAir Series provide unparalleled thermal stress testing capabilities for scientist and engineers.
- Super Quiet DC Inverter Chiller Technology
- -55°C to +125°C / +125°C to -55°C in 10 sec
- Eco-Friendly – Up to 50% Energy Savings
- Two built-in Touch Screen displays
- Control Temperature at the Test Site
- Standard Mode & Economy Mode
- Up to 20 SCFM Output Air Flow